Abstract
The practice of estimating the transfer coefficient (α) and the exchange current (i0) by arbitrarily placing a straight line on Tafel plots has led to high variance in these parameters between different research groups. Generating Tafel plots by finding kinetic current, ik from the conventional mass transfer correction method does not guarantee an accurate estimation of the α and i0. This is because a substantial difference in values of α and i0 can arise from only minor deviations in the calculated values of ik. These minor deviations are often not easy to recognise in polarisation curves and Tafel plots. Recalling the IUPAC definition of α , the Tafel plots can be alternatively represented as differential Tafel plots (DTPs) by taking the first order differential of Tafel plots with respect to overpotential. Without further complex processing of the existing raw data, many crucial observations can be made from DTP which is otherwise very difficult to observe from Tafel plots. These for example include a) many perfectly looking experimental linear Tafel plots (R2 > 0.999) can give rise to incorrect kinetic parameters b) substantial differences in values of α and i0 can arise when the limiting current (iL) is just off by 5% while performing the mass transfer correction c) irrespective of the magnitude of the double layer charging current (ic), the Tafel plots can still get significantly skewed when the ratio of i0/ic is small. Hence, in order to determine accurate values of α and i0, we show how the DTP approach can be applied to experimental polarisation curves having well defined iL, poorly defined iL and no iL at all.
Weitere Angaben
Publikationsform: | Artikel in einer Zeitschrift |
---|---|
Keywords: | Batteries; Corrosion; Electrocatalysis; Electrochemistry; Fuel cells; Metall-organic frameworks |
Themengebiete aus DDC: | 500 Naturwissenschaften und Mathematik > 540 Chemie 600 Technik, Medizin, angewandte Wissenschaften > 620 Ingenieurwissenschaften |
Institutionen der Universität: | Fakultäten > Fakultät für Ingenieurwissenschaften > Lehrstuhl Werkstoffverfahrenstechnik > Lehrstuhl Werkstoffverfahrenstechnik - Univ.-Prof. Dr.-Ing. Christina Roth Fakultäten Fakultäten > Fakultät für Ingenieurwissenschaften Fakultäten > Fakultät für Ingenieurwissenschaften > Lehrstuhl Werkstoffverfahrenstechnik |
Sprache: | Englisch |
Titel an der UBT entstanden: | Ja |
URN: | urn:nbn:de:bvb:703-epub-5871-3 |
Eingestellt am: | 28 Okt 2021 08:18 |
Letzte Änderung: | 28 Okt 2021 08:19 |
URI: | https://epub.uni-bayreuth.de/id/eprint/5871 |